Kistler,Model,4067,High,Pressure,Sensor,With,Amplifier

Kistler Model 4067 High Pressure Sensor With Amplifier

 

  Our Products

 Instrumentation
 Monitoring/Display
 Signal Conditioning


 Stress Analysis
 Strain Gauges


 Transducers
 Load/Torque Cells
 Displacement
 Pressure

 Data Acquisition

 Vibration
 Accelerometers
 Analysis


 Physical Testing
 Material/Composite
 Fatigue/Durability
 Physical


 Environmental Test
 Chambers

 



      
  Our Manufacturers
 Ashcroft
 Capacitec
 Celesco
 Chart
 Cincinnati Sub_Zero
 Data Physics
 Data Track
 Doric
 Ectron
 GP:50
 Honeywell
 Kaman
 Kistler
 Lebow Products
 Michigan Scientific
 Morehouse
 Non-Linear Devices
 Revere Transducers
 Sensortronics
 SRI PMD
 Strainsert
 Tedea-Huntleigh
 Tovey
 Trans-Tek
 Unipulse
 Vishay Measurements
 Group
 
  Kistler Model 4067 High Pressure Sensor With Amplifier
High pressure sensor with rugged diaphragm and front seal for measuring on hydraulic systems, (e.g. fuel injection systems of internal combustion engines), and gas pressure measurements. Suitable for static and dynamic pressures. Its small dimensions allow its use with a clamp adapter on the injection pipe. High natural frequency.

This is one of the smallest sensors on the market for static measurement. It is supplied together with amplifier Type 4618A Option with Type 4620A2 (total error < 0.5%, fg > 300 Hz) upon request.

The pressure to be measured acts through a rugged diaphragm on an arrangement of piezoresistive rods. The pressure changes the values of the resistance's diffused into the rods. These resistance's are arranged in a Wheatstone bridge.

The pressure sensor itself is not temperature compensated. The amplifier Type 4618 provides temperature compensation, linearization of the pressure signal and contains a stabilized power supply. For this reason, the sensor must always be operated with the amplifier adjusted to it. Amplifier Type 4618 additionally contains two adjustable limit switches with optocouplers. A version with simultaneous temperature measurement is available as an option.

Sensor Type 4067 is used appropriately wherever high pressures with a static component have to be measured in confined spaces. Examples are the fine tuning of injection systems and diesel engines or measurements on hydraulic systems.

• Measuring range up to 5000 bar
• Measures static and dynamic pressures
• High natural frequency

Kistler Model 4067 High Pressure Sensor With Amplifier


 

Kistler Model 4067 High Pressure Sensor With Amplifier